3M™ Molecular Detection System (MDS) – Molecular Pathogen Detection System

Fiyat Sorunuz

Food pathogen detection system utilizing LAMP DNA amplification technology. Rapidly and reliably detects pathogens including Salmonella, Listeria, and Listeria monocytogenes.

  • High sensitivity and specificity with LAMP DNA amplification technology
  • Simplified workflow with only two pipetting steps
  • Amplification results available in approximately 15 minutes
  • Final results for most food matrices within one day
  • AFNOR NF Validation and AOAC® Official Methods of Analysis approval
  • Multi-pathogen testing support including Salmonella, Listeria, and Listeria monocytogenes

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

3M™ Molecular Detection System (MDS) is a molecular detection platform designed to accelerate pathogen screening in food safety laboratories. Based on LAMP (Loop-Mediated Isothermal Amplification) DNA amplification technology, it delivers results with high sensitivity and specificity.

The system features ready-to-use reagents and a simplified workflow requiring only two pipetting steps: one for sample lysis of enriched samples, and one for preparing the DNA amplification reaction. This reduces analysis time and minimizes operator error risk. Amplification results can be obtained in as little as 15 minutes depending on the assay, while final results for most food matrices are typically available the next day.

The system holds AFNOR Certification with NF Validation and approvals from internationally recognized organizations including AOAC® Official Methods of Analysis. It is compatible with 3M™ Molecular Detection Assay 2 kits for various pathogens such as Salmonella, Listeria, and Listeria monocytogenes, enabling simultaneous screening of multiple pathogens and reducing labor and time costs.

Ideal for food manufacturers, quality control laboratories, and independent testing laboratories seeking a reliable, rapid, and user-friendly pathogen screening solution.

Technical Specifications

Manufacturer 3M™ Neogen®
Technology LAMP DNA Amplification
Result Time (Amplification) ~15 minutes
Result Time (Overall) Next day for most food matrices
Certifications AFNOR NF Validation, AOAC® Official Methods of Analysis, AOAC® Performance Tested Methods
Compatible Assays 3M™ Molecular Detection Assay 2 – Salmonella, Listeria, Listeria monocytogenes

Applications

  • Pathogen screening in food production facilities
  • Rapid result requirements in quality control laboratories
  • Multi-pathogen analysis in independent food testing laboratories

Frequently Asked Questions

What pathogens can the MDS system detect?
The system is compatible with 3M™ Molecular Detection Assay 2 kits and can detect various pathogens including Salmonella, Listeria, and Listeria monocytogenes.
How quickly are results obtained?
Amplification results can be obtained in approximately 15 minutes depending on the assay, while final results for most food matrices are typically available the next day.
Does the system have international approvals?
Yes, the system holds AFNOR Certification with NF Validation and AOAC® Official Methods of Analysis approval.