Stoklu siparişleriniz aynı gün kargoda!

CheckPoint3 PBI DANSENSOR Portable Gas Analysis Instrument for Modified Atmosphere Package (MAP) Quality Control

Fiyat Sorunuz

Advanced portable gas analyzer for rapid O2 and CO2 level verification in Modified Atmosphere Packages of all shapes and sizes

This product is currently out of stock and unavailable.

  • Most advanced portable gas analyzer for MAP quality control
  • Electrochemical sensor for high oxygen concentration applications
  • Fastest analysis: 7-second sampling time with 5 ml minimum sample volume
  • Highest sensitivity in portable analyzers with extended sensor lifetime
  • WiFi connectivity with intuitive color display for easy data management
  • Optical sensor provides highest accuracy among comparable instruments
  • Improved process efficiency and low cost of ownership
  • Extended memory: up to 1 million measurements
  • 12-month calibration and service included

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The CheckPoint 3 is the most advanced portable gas analysis instrument on the market, enabling fast and easy monitoring of O2 and CO2 levels in Modified Atmosphere Packages (MAP) of any shape and size. Now featuring electrochemical sensor technology designed for food applications including headspace environments with high oxygen concentrations. With extended sensor life, CheckPoint 3 offers the highest sensitivity level in portable analyzers, WiFi connectivity for reliable data management, and intuitive interface with color display for excellent process visibility and traceability.

Technical Specifications

Available Configurations O2 (ceramic solid state sensor) | O2 (electrochemical sensor) | CO2 (infrared single-beam sensor)
Minimum Sample Volume 5 ml
Minimum Sampling Time 7 seconds
Measurement Range O2 (Ceramic) 0-55%
Measurement Range O2 (Electrochemical) 0-100%
Measurement Range CO2 0-100%
Resolution 0.1% O2 / 0.1% CO2
Sensor Accuracy O2 (Ceramic) ±(0.1% O2 + 2% of reading)
Sensor Accuracy O2 (Electrochemical) ±(0.25% O2 + 2% of reading)
Sensor Accuracy CO2 ±2% CO2 (0-20% range) | ±3% CO2 (20-100% range)
Warm-up Time 5 seconds (ceramic sensor) | None (electrochemical)
Expected Sensor Lifetime >3 years (ceramic) | >1 year (electrochemical, usage dependent) | >5 years (CO2)
Dimensions 75 x 100 x 175 mm (H x W x D)
Weight 0.7 kg
Power Supply Battery-powered; up to 2000 measurements per full charge at 20°C; maximum charge time 5 hours
Connectivity WiFi (WPA, WPA2, WPA Enterprise)
Data Storage Extended memory – up to 1 million measurements
Operating Temperature 0 to +40°C, <95% relative humidity, non-condensing
Compliance RoHS, China RoHS, CE
Calibration and Service 12 months
Standard Accessories Included 100 septums, 10 needles (Ø 0.8), 10 water-trap filters, interchangeable power plug (USA, EU, AU, UK)
Optional Accessories Standard consumables kit (1 sampling kit, 1000 septums, 10 needles (Ø 0.8) and 10 water-trap filters), metal needles

Applications

  • Bread (alcohol-treated)
  • Coffee
  • Fermented products
  • Fish (smoked)
  • Fresh pasta
  • Red and smoked meat
  • Raw and prepared vegetables
  • Processed meat
  • Raw and prepared fish
  • Cheese
  • Ready-to-eat meals
  • Snack foods
  • Beverages
  • All food applications (CO2 configuration)

Frequently Asked Questions

What is the CheckPoint 3 used for?
The CheckPoint 3 is a portable gas analysis instrument designed for rapid quality control of oxygen (O2) and carbon dioxide (CO2) levels in Modified Atmosphere Packages (MAP) across the food industry. It ensures package integrity and proper gas composition for extended shelf life.
What sensor options are available?
Three configurations are available: ceramic solid state sensor for O2 (0-55% range, best for low oxygen applications), electrochemical sensor for O2 (0-100% range, suitable for high headspace oxygen concentrations), and infrared single-beam sensor for CO2 (0-100% range).
How long does a measurement take?
Minimum sampling time is 7 seconds with a minimum sample volume of just 5 ml, providing rapid quality control results.
What is the sensor accuracy?
Ceramic O2 sensor: ±(0.1% O2 + 2% of reading); Electrochemical O2 sensor: ±(0.25% O2 + 2% of reading); CO2 sensor: ±2% (0-20% range) or ±3% (20-100% range)
How long do the sensors last?
Expected lifetimes: Ceramic O2 sensor >3 years, Electrochemical O2 sensor >1 year (usage dependent), CO2 sensor >5 years. The new extended sensor life provides excellent value.
Does the CheckPoint 3 have data connectivity?
Yes, the CheckPoint 3 features WiFi connectivity (WPA, WPA2, WPA Enterprise) with an intuitive color display interface for reliable, easy data management and traceability.
How much data can it store?
The instrument has extended memory capacity to store up to 1 million measurements, enabling comprehensive historical data tracking and analysis.
What is the battery life?
A fully charged battery at 20°C provides up to 2000 measurements. Charge time is maximum 5 hours.
What food applications is it suitable for?
The electrochemical sensor version is designed for: red and smoked meat, smoked fish, alcohol-treated bread, fresh pasta, fermented foods, and coffee. The ceramic sensor version covers vegetables, processed meat, fresh fish, cheese, ready-to-eat meals, snack foods, and beverages. The CO2 sensor covers all food applications.
What maintenance is required?
The CheckPoint 3 includes 12 months calibration and service. Standard consumables kit includes 1000 septums, needles, and water-trap filters for continuous operation.
What operating conditions does it require?
Operating temperature range: 0 to +40°C with relative humidity <95%, non-condensing conditions required.
What is the cost of ownership advantage?
The CheckPoint 3 offers improved process efficiency combined with low cost of ownership through extended sensor life, energy-efficient battery operation, and reliable performance that reduces product waste and recalls.