Stoklu siparişleriniz aynı gün kargoda!

BioTek Epoch 2 Microplate Spectrophotometer

Fiyat Sorunuz

Microplate reader measuring UV-Vis absorbance in 6-384 well plates and Take3 micro-volume plate. Suitable for ELISA, nucleic acid/protein quantification, and kinetic assays.

  • Monochromator-based UV-Vis wavelength selection from 200-999 nm
  • Compatibility with 6-384 well plates and Take3 Micro-Volume Plate (2 µL)
  • 4-Zone incubation up to 65°C with Condensation Control
  • Linear, orbital, and double-orbital shaking modes
  • Gen5 Data Analysis Software with 21 CFR Part 11 compliant Gen5 Secure option
  • Automation compatibility with BioStack and BioSpa 8

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

BioTek Epoch 2 is a microplate spectrophotometer measuring UV-Vis absorbance in 6-384 well microplates and with Take3 Micro-Volume Plate for samples as low as 2 µL. It serves a broad application range including ELISA, cellular/microbial growth monitoring, nucleic acid and protein quantification, and kinetic assays.

The instrument provides monochromator-based wavelength selection (200-999 nm, 1 nm increments) and Xenon flash light source enabling filter-free UV-Vis scanning capability. It supports endpoint, kinetic, spectral scan, and well-area scan reading modes. 4-Zone incubation up to 65°C with Condensation Control ensures consistency in temperature-sensitive assays; linear, orbital, and double-orbital shaking options assist in sample homogenization.

Data collection and analysis are performed with Gen5 Data Analysis Software; Gen5 Secure option is available for 21 CFR Part 11 compliance. Workflow automation is enabled through compatibility with BioStack and third-party automation systems as well as BioSpa 8 Automated Incubator.

With its flexibility to work in both cuvette and microplate formats, it provides a practical solution for both routine and research laboratories.

Technical Specifications

Manufacturer BioTek
Detection mode Absorbance
Reading methods Endpoint, kinetic, spectral scan, well-area scan
Microplate compatibility 6-384 well plates
Micro-volume measurement Take3 Micro-Volume Plate, 2 µL
Temperature control 4-Zone incubation, up to 65°C, Condensation Control
Additional temperature control range 37°C ±0.2°C
Shaking modes Linear, orbital, double-orbital
Light source Xenon flash
Detector Photodiode
Wavelength selection Monochromator
Wavelength range 200-999 nm, 1 nm increments
Monochromator bandwidth 2.9 nm
Dynamic range 0-4.0 OD
Resolution 0.0001 OD
Pathlength correction Yes
Monochromator wavelength accuracy ±2 nm
Monochromator wavelength repeatability ±0.2 nm
Software Gen5 Data Analysis Software (Gen5 Secure optional)
Automation compatibility BioStack, BioSpa 8, third-party automation

Applications

  • ELISA assays
  • Cellular and microbial growth monitoring
  • Nucleic acid and protein quantification (micro-volume)
  • Kinetic enzyme assays

Frequently Asked Questions

What microplate formats does Epoch 2 support?
It supports 6-384 well microplates and cuvette measurements with Take3 Micro-Volume Plate.
Can micro-volume samples be measured?
Yes, samples down to 2 µL can be measured with the Take3 Micro-Volume Plate.
Can it be integrated with automation systems?
Yes, it is compatible with BioStack, BioSpa 8 Automated Incubator, and third-party automation systems.