Combi Afla+Ochra Immunoaffinity Columns

Fiyat Sorunuz

Pre-packed immunoaffinity columns for simultaneous extraction of aflatoxins and ochratoxins in food and feed analysis

  • Simultaneous extraction of aflatoxins and ochratoxins in single column
  • 50 columns per package, 3 mL volume each
  • High recovery rates: >85% for aflatoxins, >90% for ochratoxin A
  • Zero contamination verified by HPLC LOD (<0.04 ng)
  • Compatible with LC-MS/MS and HPLC systems
  • Wide working range: 0.04–200 ng per IAC
  • Maximum capacity: 1.8 µg aflatoxin, 3 µg ochratoxin per column

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

Combi Afla+Ochra immunoaffinity columns are optimized for simultaneous extraction of aflatoxins and ochratoxins from food and feed matrices. Each package contains 50 prepacked columns with 3 mL volume, delivering high sensitivity and reliability for LC-MS/MS and HPLC analytical methods. The columns provide consistent performance and are validated for regulatory compliance testing.

Technical Specifications

Package Contents 50 columns per package, 3 mL each
Working Range Aflatoxins: 0.04–200 ng per IAC; Ochratoxin: 0.04–200 ng per IAC
Column Blank Contamination (HPLC LOD) Aflatoxin: <0.04 ng; Ochratoxin: <0.04 ng
Recovery Rates (Guaranteed) Total Aflatoxin: >85% ± 5%; AFB1: >95% ± 5%; AFB2: >85% ± 5%; AFG1: >85% ± 5%; AFG2: >85% ± 5%; OTA: >90% ± 5%
Maximum Column Capacity Total Aflatoxin: 1.8 µg; Ochratoxin: 3 µg per IAC
Analyte Cross Reactivity AFB1: 100%; AFB2: 99%; AFG1: 48%; AFG2: 34%; OTA: 100%; OTB: 103%

Applications

  • Aflatoxin screening in cereal grains and grain products
  • Ochratoxin A detection in coffee, cocoa, and dried fruits
  • Multi-analyte detection in mixed feed matrices
  • Regulatory compliance testing for food safety standards
  • Qualitative and quantitative HPLC analysis
  • LC-MS/MS confirmation methods
  • Mycotoxin monitoring in agricultural commodities

Frequently Asked Questions

What is the minimum sample volume required for analysis?
The 3 mL column volume accommodates standard sample extracts. Refer to the application protocol for specific sample preparation requirements.
Are the columns compatible with automated sample preparation systems?
Yes, the standard 3 mL column format is compatible with most automated extraction platforms used in food analysis laboratories.
What is the shelf life of these immunoaffinity columns?
Shelf life specifications are available upon request from Novatek Analitik Sistemler A.Ş. Storage conditions must follow manufacturer guidelines.
Can these columns detect other mycotoxins besides aflatoxins and ochratoxins?
These columns are specifically designed and validated for aflatoxins (B1, B2, G1, G2) and ochratoxin A/B detection. For other mycotoxins, dedicated columns are recommended.
What analytical instruments are compatible with these columns?
The columns are validated for use with HPLC and LC-MS/MS systems for both qualitative and quantitative analysis.