Stoklu siparişleriniz aynı gün kargoda!

Atago 2471 Master-S10α Handheld Refractometer – 0-10% NaCl Salinity Meter

Fiyat Sorunuz

Handheld refractometer measuring salinity in the 0.0%-10.0% NaCl range with automatic temperature compensation and metal housing. Practical measurement solution for food, water, and salt industry applications.

  • 0.0%-10.0% NaCl measurement range
  • ±0.2% measurement accuracy
  • 0.2% resolution
  • Automatic temperature compensation (10-30°C)
  • Durable metal housing
  • Requires only 2-3 drops of sample per measurement

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The Atago 2471 Master-S10α is a durable, handheld refractometer designed to measure sodium chloride (NaCl) concentration in liquid samples within the 0.0%-10.0% range. The instrument delivers fast, repeatable results using only 2-3 drops of sample.

With automatic temperature compensation, the device minimizes measurement deviation across ambient temperatures from 10-30°C. The ±0.2% measurement accuracy and 0.2% resolution ensure reliable performance in food quality control, water and salt industry monitoring, and aquaculture/marine applications.

The metal housing construction provides robust durability suitable for both laboratory and field use. Operating on the simple prism reading principle, the instrument enables rapid measurements immediately after calibration.

Technical Specifications

Model Master-S10α
Catalog Number 2471
Measurement Range 0.0% – 10.0% NaCl
Measurement Accuracy ± 0.2%
Resolution 0.2%
Temperature Compensation Automatic
Operating Temperature 10-30°C
Housing Material Metal
Dimensions & Weight 3.2(W) x 3.4(D) x 16.8(H) cm, 130g

Applications

  • Salinity measurement in water and salt industry applications
  • Quality control in food laboratories
  • Water quality monitoring in marine and aquaculture environments

Frequently Asked Questions

What measurement range does the Master-S10α cover?
The instrument measures salinity from 0.0% to 10.0% NaCl concentration.
How much sample is required for measurement?
Only 2-3 drops of sample are needed per measurement.
Does ambient temperature affect the measurement results?
The device features automatic temperature compensation across the 10-30°C range, which minimizes measurement deviation caused by temperature variations.