Stoklu siparişleriniz aynı gün kargoda!

Atago NAR-2T-UH Abbe Refractometer (Ultra-High Refractive Index)

Fiyat Sorunuz

Abbe refractometer for ultra-high refractive index special optical materials and crystal analysis, measuring in the range 1.7000-2.0800 nD and up to 120°C.

  • Refractive index measurement range: 1.7000 - 2.0800 nD
  • Measurement temperature: 5 - 120°C
  • Accuracy: ±0.0002 nD
  • Minimum scale division: 0.001
  • LED (D-Line) light source
  • nF-nC dispersion calculation (via tables)

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The NAR-2T-UH is Atago's high-index and high-temperature model in the NAR-2T series. With a wide refractive index range of 1.7000 to 2.0800 nD and measurement temperature capability of 5-120°C, it is used for analysis of high-index crystals and specialized optical materials that standard refractometers cannot measure.

The instrument delivers precise measurement with ±0.0002 nD accuracy and 0.001 minimum scale division. It uses an LED (D-Line) light source and provides nF-nC dispersion calculation capability via reference tables. The unit does not feature IP65 protection or automatic temperature compensation; therefore, careful temperature control during measurement is essential.

It is particularly suited for laboratories requiring high-temperature crystal growth processes, specialized glass and optical material development work, and characterization of high-index specimens.

Technical Specifications

Manufacturer Atago
Model NAR-2T·UH
Catalog No. 1229
Refractive Index (nD) 1.7000 – 2.0800
Minimum Scale Division 0.001
Measurement Temperature 5 – 120°C
Accuracy ±0.0002 nD
Dispersion nF-nC (Via tables)
Light Source LED (D-Line)
IP65 Protection None
Temperature Compensation None

Applications

  • High-index crystal and optical material analysis
  • High-temperature crystal growth process control
  • Specialized glass and optical material development laboratories

Frequently Asked Questions

What refractive index range can the NAR-2T-UH measure?
It can measure values between 1.7000 and 2.0800 nD with ±0.0002 nD accuracy.
Does the instrument have automatic temperature compensation?
No, the instrument does not feature automatic temperature compensation; measurement temperature must be controlled manually.
What is the maximum measurement temperature?
The instrument can perform measurements between 5°C and 120°C.