Handheld optical particle counter for ISO cleanroom certification and air quality monitoring with RS-232 data communication

  • Triple-channel optical measurement at 0.3, 0.5, and 5.0 µm particle diameters
  • Laser diode light source with <1 zero count per 5 minutes (JIS-compliant)
  • 0.1 CFM (2.83 LPM) isokinetic sampling flow rate
  • Maximum concentration range >2,000,000 particles/ft³ at 5% coincidence loss
  • 50% ± 20% counting efficiency (first channel, JIS-verified)
  • ISO 5-8 cleanroom classification certification capability
  • Internal memory: 10,000 measurement datasets with secure read-only archive
  • Real-time LCD display with printer output and ISO reporting mode
  • CSV export to Excel for statistical analysis and trend documentation

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

Compact laboratory particle counter featuring laser diode optical detection system for real-time aerosol measurement across three size channels (0.3, 0.5, 5.0 µm). Engineered for cleanroom classification, pharmaceutical manufacturing, and environmental monitoring applications. Delivers simultaneous multi-channel particle concentration readings with ISO 5-8 compliance capability. Integrates 4-line LCD display, internal data logging for 10,000 measurements, and PC connectivity via RS-232 interface. Operates on dual-mode power system (AC adapter or NiMH battery pack) for laboratory and field deployment flexibility.

Technical Specifications

Measurement Channels 0.3, 0.5, and 5.0 µm
Sample Flow Rate 0.1 CFM (2.83 LPM)
Light Source Laser diode
Maximum Concentration >2,000,000 particles/ft³ @ 5% coincidence loss
Zero Count Specification <1 count in 5 minutes (JIS Japanese Industrial Standards compliant)
Counting Efficiency 50% ± 20% first channel (JIS-verified)
Outlet Filter None
Data Interface RS-232 serial, 9600 baud rate
Display Type 4-line LCD
Measurement Units Particle count, particles/m³, particles/ft³
ISO Certification ISO 5-8 @ 0.5 and 5.0 µm
Report Functions Single/multiple/continuous measurement printing; ISO mode calculation; external printer compatible
Data Export CSV format (Excel-compatible)
Internal Storage 10,000 measurements (calculations require 2 record slots)
Data Protection Write-protected archived records
Housing Material ABS polymer
Surface Cleaning Methanol or neutral detergent compatible
Power Supply 100-264V 50-60Hz AC adapter OR 4× AA NiMH rechargeable batteries
Battery Runtime 3 hours continuous operation
Dimensions (H×W×D) 4.3 × 7.6 × 2.7 inches (11 × 20 × 7 cm)
Weight (Battery-free) 1.5 lb (0.68 kg)
Included Accessories Isokinetic sampling probe, AC adapter, zero-air filter cartridge, user manual, 4× AA NiMH batteries, RS-232 cable, instrument stand, CSV transfer software
Optional Accessories External thermal printer, printer paper rolls, transport case, tripod mount

Applications

  • ISO 5-8 cleanroom certification and periodic recertification testing
  • Pharmaceutical sterile facility environmental monitoring
  • Medical device manufacturing cleanroom validation
  • Semiconductor fabrication facility particle classification
  • Biotechnology laboratory air quality assurance
  • Hospital operating theater cleanroom surveillance
  • Indoor air quality assessment and post-remediation verification
  • HVAC system performance monitoring and filter efficiency testing
  • Contamination control during equipment installation and maintenance
  • Field particle counting for portable laboratory applications

Frequently Asked Questions

What is the difference between the three measurement channels (0.3, 0.5, 5.0 µm)?
The particle counter simultaneously measures particles across three size classifications. The 0.3 µm channel detects ultrafine particles, 0.5 µm captures fine particulates (ISO standard reference), and 5.0 µm identifies larger contamination events. Multi-channel measurement enables comprehensive cleanroom compliance documentation.
Is this particle counter suitable for ISO cleanroom certification?
Yes. The instrument is certified for ISO 5-8 cleanroom classification at 0.5 and 5.0 µm particle sizes. It meets JIS (Japanese Industrial Standards) zero count and counting efficiency specifications required for official cleanroom qualification.
What does '<1 zero count in 5 minutes' mean?
This specification indicates that when sampling particle-free air (through the zero-air filter), the instrument registers fewer than 1 false particle count during a 5-minute sampling period. Lower zero counts ensure measurement accuracy and sensitivity.
Can I export data to Excel or other analysis software?
Yes. The particle counter stores up to 10,000 measurements internally and exports all data via CSV format, which is fully compatible with Microsoft Excel, statistical software, and laboratory information systems (LIMS).
How long does the battery last?
The 4×AA NiMH rechargeable battery pack provides approximately 3 hours of continuous particle counting operation, sufficient for field sampling protocols. The AC adapter enables extended laboratory use without battery limitations.
What is the maximum particle concentration this counter can measure?
The instrument can measure up to 2,000,000 particles/ft³ at 5% coincidence loss. Coincidence loss (when two particles are counted as one) increases at very high concentrations. Dilution sampling may be required for higher contamination levels.
Is external software or calibration required?
The counter functions with internal firmware and integrated display controls. No external software installation is necessary for operation. Optional CSV data transfer software facilitates Excel import. Factory calibration maintains measurement traceability; recalibration is recommended per facility SOP.
What maintenance does the particle counter require?
Regular maintenance includes: replacing zero-air filters when saturated, cleaning the external ABS housing with methanol or neutral detergent, verifying battery charging cycles, and periodic optical system inspection. Refer to the user manual for detailed maintenance schedules.
Can I connect the particle counter to a printer for automated reporting?
Yes. The RS-232 interface (9600 baud rate) supports connection to external thermal printers. The instrument generates single, multiple, or continuous measurement printouts with ISO classification calculations and certified documentation.
What is the sampling head, and why is it included?
The isokinetic sampling probe maintains representative air velocity at the measurement inlet, ensuring accurate particle collection regardless of ambient air speed. This is essential for valid cleanroom certification and reproducible environmental monitoring.