Stoklu siparişleriniz aynı gün kargoda!

Pocket-sized Calcium Ion Meter HORIBA LaquaTwin B751

Fiyat Sorunuz

Ca²⁺ Ion-Selective Electrode (ISE) Portable Meter for On-Site Field Measurement

  • Ion-selective electrode (ISE) technology for ionized calcium measurement
  • Measurement range: 40 to 4000 ppm (mg/L)
  • Automatic range switching and temperature compensation
  • IP67 water/dust resistant construction
  • Auto-hold and auto-shutoff (30 minutes) functions
  • Two-point calibration capability
  • Compact pocket-sized design: 164 × 29 × 20 mm
  • Approximately 400 hours battery life (CR2032 × 2)

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

Ion-selective electrode method enables precise on-site measurement of ionized calcium concentration. The HORIBA LaquaTwin B751 is a compact, portable analyzer designed for rapid analysis of calcium ions in soil, water, agricultural, food, and biomedical applications. Features automatic range switching, temperature compensation, and IP67 water/dust resistance for reliable field use.

Technical Specifications

Model B-751
Measurement Principle Ion-selective electrode (ISE) method
Measurement Range 40 to 4000 ppm (mg/L) (10⁻³ to 10⁻¹ mol/L)
Display Range 0 to 9900 ppm (mg/L)
Range & Resolution 0-1.0 ppm: 0.1 ppm | 0-99 ppm: 1 ppm | 100-990 ppm: 10 ppm | 1000-9900 ppm: 100 ppm
Accuracy ±20% of reading
Display Custom monochrome digital LCD
Operating Temperature/Humidity 5 to 40°C at relative humidity ≤85% (no condensation)
Power Supply CR2032 batteries (×2)
Battery Life Approx. 400 hours continuous use
Primary Material ABS epoxy
Dimensions/Weight 164 mm × 29 mm × 20 mm (excluding protrusions) / Approx. 50 g (battery excluded)
Interfering Ion Selectivity Coefficients & pH Range Na⁺, K⁺, Mg²⁺ = 1×10⁻³ | Fe²⁺, Zn²⁺ = 1 | Fe³⁺ = 10⁻² | Cu²⁺ = 1×10⁻² | pH range 4 to 10 for ~12×10⁻³ mol/L Ca²⁺

Applications

  • Soil testing and nutrient analysis
  • Food quality control and processing verification
  • Crop and yield management monitoring
  • Clinical and health management applications
  • Coral restoration and aquaculture management
  • Water hardness measurement and assessment

Frequently Asked Questions

What measurement principle does the LaquaTwin B751 use?
The instrument uses ion-selective electrode (ISE) technology, which directly measures the concentration of ionized calcium (Ca²⁺) in the sample without pre-treatment.
Is the B751 suitable for field use?
Yes. The meter is pocket-sized, IP67 water/dust resistant, powered by standard CR2032 batteries, and features auto-hold and auto-shutoff functions, making it ideal for on-site field measurements.
What is the accuracy of the B751?
The accuracy is ±20% of the reading value across the measurement range.
How long does the battery last?
With CR2032 batteries (×2), continuous battery life is approximately 400 hours.
Does temperature affect the measurement?
Temperature variation can affect ion readings. The B751 includes automatic temperature compensation to maintain accuracy between 5 to 40°C.