Stoklu siparişleriniz aynı gün kargoda!

APERA 2301T-S Conductivity Electrode

Fiyat Sorunuz

APERA 2301T-S Conductivity/Temperature Electrode featuring advanced BPB conductivity sensor technology for precise measurements across wide range with built-in thermistor and automatic temperature compensation.

  • Advanced BPB conductivity sensor technology for superior accuracy
  • Built-in thermistor for simultaneous temperature measurement
  • Automatic temperature compensation (ATC) capability
  • Wide measurement range from 0.5 μS/cm to 200 mS/cm
  • Suitable for laboratory and field applications
  • BNC 8-pin connector for secure connection

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The APERA Instruments 2301T-S Conductivity/Temperature Electrode incorporates Apera's unique BPB conductivity sensor technology, delivering high accuracy across an extensive conductivity measurement range. The integrated thermistor simultaneously measures temperature and enables automatic temperature compensation (ATC). Designed for both routine laboratory and field use, this probe sensor is compatible with multiple Apera meter models.

Technical Specifications

Measurement Range 0.5 μS/cm to 200 mS/cm
Cell Constant K = 1.0 ± 0.2 cm⁻¹
Dimensions ø12 × 155 mm
Connector Type BNC 8-pin

Applications

  • Laboratory conductivity testing and analysis
  • Water quality monitoring in field applications
  • Industrial process control and monitoring
  • Environmental water sampling and analysis
  • Educational laboratory demonstrations
  • Pharmaceutical and chemical solution testing

Frequently Asked Questions

Which Apera meter models are compatible with the 2301T-S electrode?
The 2301T-S electrode is compatible with the following Apera models: SX823-B, EC400, PC400, EC400S, and PC400S.
Does the 2301T-S electrode include temperature measurement capability?
Yes, the electrode features a built-in thermistor that simultaneously measures temperature and enables automatic temperature compensation (ATC) for accurate conductivity readings across varying temperatures.
What is the cell constant and why is it important?
The cell constant (K = 1.0 ± 0.2 cm⁻¹) is a calibration factor that relates the measured conductance to the actual conductivity of a solution. It is essential for accurate conductivity measurements.
Can the 2301T-S be used for both laboratory and field applications?
Yes, the 2301T-S electrode is designed for versatile use in both routine laboratory settings and field applications, making it ideal for diverse testing scenarios.