Stoklu siparişleriniz aynı gün kargoda!

Laboratory Fume Hood – Pag Laboratory | Novatek Analitik

Fiyat Sorunuz

Laboratory fume hood operating on negative pressure principle; safely exhausts harmful gases, vapors, and particulates while capturing them with HEPA/carbon filters.

  • Effective gas/vapor exhaust via negative pressure principle
  • HEPA, activated carbon, and prefilter combination
  • Adjustable air flow rate 100-1200 m³/hour
  • Low noise level ≤60 dB(A)
  • Stainless steel and tempered glass construction
  • Manual and automatic sensor-based control options

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

Laboratory fume hoods protect laboratory personnel by preventing chemical vapors and particulates from dispersing into the work environment. The negative pressure-based system maintains interior cabinet pressure lower than the external environment, drawing harmful substances directly into the hood and exhausting them after filtration.

Used in chemistry, biology, pharmaceutical, and industrial laboratories, these systems employ HEPA, activated carbon, and prefilter combinations to capture particulates and chemical vapors with high efficiency. The fan-driven exhaust system provides adjustable air flow rates between 100-1200 m³/hour depending on model and application. The stainless steel body and tempered glass construction deliver chemical resistance and visual monitoring capability.

Manual or sensor-based automatic air flow control systems optimize energy consumption while maintaining noise levels below 60 dB(A). Benchtop, wall-mounted, or standalone installation options adapt to any laboratory layout. Custom-sized configurations are available in addition to standard dimensions.

Technical Specifications

Operating Principle Negative pressure air intake and exhaust
Filter Types HEPA, Activated Carbon, Prefilter
Air Flow Rate 100 – 1200 m³/hour (varies by model)
Noise Level ≤ 60 dB(A)
Material Stainless steel, tempered glass
Dimensions Standard and custom sizes
Power Consumption 50 – 200 W (varies by model)
Control System Manual and automatic (sensor-based) air flow control
Installation Type Benchtop, wall-mounted, standalone
Manufacturer Pag Laboratory

Applications

  • Volatile and toxic chemical handling in chemistry laboratories
  • Pharmaceutical formulation and sample preparation in pharmacy laboratories
  • Hazardous vapor/gas experiments in biology laboratories
  • Chemical analysis processes in industrial laboratories

Frequently Asked Questions

What air flow rate does the fume hood provide?
Air flow rates range between 100-1200 m³/hour depending on model and application.
Which filter types are used?
The HEPA, activated carbon, and prefilter combination effectively captures particulates and chemical vapors.
What installation options are available?
Benchtop, wall-mounted, and standalone models are available; custom-sized configurations can also be manufactured.