Stoklu siparişleriniz aynı gün kargoda!

Atago PAL-26S Mannitol Refractometer – Digital Concentration Meter

Fiyat Sorunuz

Digital handheld refractometer for simultaneous measurement of mannitol concentration and temperature. Delivers results in 3 seconds with only 2-3 sample drops, ideal for pharmaceutical manufacturing and quality control.

  • 0.0-15.0% mannitol measurement range, 0.1% resolution
  • 10.0-40.0°C temperature measurement, 0.1°C resolution
  • ±0.3% mannitol, ±1°C temperature accuracy
  • Results in ~3 seconds with only 2-3 sample drops
  • IP65 water-resistant housing
  • Portable operation with 2 × AAA batteries

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The PAL-26S is a specialized digital handheld refractometer designed for concentration and temperature measurement of mannitol-based pharmaceutical solutions. With a measurement range of 0.0-15.0% mannitol and temperature measurement capacity of 10.0-40.0°C, it provides rapid and reproducible results for parenteral solution manufacturing, drug formulation, and hospital pharmacy and clinical research laboratory applications.

The instrument performs measurements with ±0.3% mannitol and ±1°C temperature accuracy at 0.1% and 0.1°C resolution respectively. Requiring only 2-3 sample drops and delivering results in approximately 3 seconds, it is well-suited for rapid quality control processes. Its IP65 water-resistant housing ensures durable operation in manufacturing and laboratory environments, while operation via 2 AAA batteries provides portable measurement capability.

It is a practical solution for pharmaceutical R&D, production line quality control, and clinical research laboratories requiring precise monitoring of mannitol concentration.

Technical Specifications

Model PAL-26S
Catalog Number 4426
Measurement Parameter Mannitol and Temperature
Mannitol Range 0.0 – 15.0% (g/100g)
Temperature Range 10.0 – 40.0°C
Mannitol Resolution 0.1%
Temperature Resolution 0.1°C
Mannitol Accuracy ±0.3%
Temperature Accuracy ±1°C
Operating Temperature 10 – 40°C
Sample Volume 2-3 drops
Measurement Time Approximately 3 seconds
Power Supply 2 × AAA Batteries
Protection Rating IP65 Water-Resistant
Dimensions 5.5 × 3.1 × 10.9 cm
Manufacturer Atago

Applications

  • Mannitol concentration control in pharmaceutical parenteral solution manufacturing
  • Rapid analysis in drug formulation R&D studies
  • Quality control in hospital pharmacy and clinical research laboratories

Frequently Asked Questions

Does the PAL-26S measure only mannitol?
Yes, the instrument is specifically calibrated for mannitol concentration and temperature measurement; it is not designed for general Brix measurement.
Does it have automatic temperature compensation?
No, the instrument does not feature automatic temperature compensation; measurement temperature is monitored and reported separately.
How much sample is required?
Only 2-3 drops of sample are needed for measurement, with results obtained in approximately 3 seconds.