Hastelloy wetted-parts in-line Brix monitor. Provides continuous process measurement with ±0.1% accuracy in the 0-80.0% Brix range. Suitable for production lines operating in corrosive environments.

  • Measurement range: 0.0-80.0% Brix
  • Accuracy: ±0.1%, Resolution: 0.01%
  • Wetted parts: Hastelloy (superior corrosion resistance)
  • Operating temperature: -15°C to 160°C
  • Outputs: RS-232C and 4-20mA
  • IP65 rated; automatic temperature compensation not included

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The Atago CM-800α-Hastelloy is an in-line refractometer designed for process streams requiring continuous Brix measurement in aggressive chemical environments. With Hastelloy wetted-part construction, it performs reliably in chloride-bearing and mixed-acid applications. The instrument integrates with SCADA/PLC systems via RS-232C digital and 4-20mA analog outputs.

The device measures across 0.0-80.0% Brix with ±0.1% accuracy and 0.01% resolution. Operating temperature range from -15°C to 160°C enables use in elevated-temperature process streams. IP65 enclosure rating provides field-installation protection; however, automatic temperature compensation is not featured, so process thermal fluctuations must be evaluated independently during commissioning.

This in-line series model from Atago is specified for applications where standard SUS316L wetted-part versions are insufficient and corrosion resistance is critical to process continuity.

Technical Specifications

Manufacturer Atago
Model CM-800α-Hastelloy
Catalog Number 3513
Measurement Range 0.0-80.0% Brix
Accuracy ±0.1%
Resolution 0.01%
Operating Temperature -15°C to 160°C
Wetted Parts Hastelloy
Output RS-232C / 4-20mA
IP Rating IP65
Temperature Compensation Not included

Applications

  • Continuous Brix monitoring in corrosive process streams containing chlorides or mixed acids
  • Elevated-temperature (up to 160°C) process stream surveillance
  • SCADA/PLC-integrated continuous concentration tracking in automated production systems

Frequently Asked Questions

In which environments should the CM-800α-Hastelloy be used?
This model is specified for aggressive chemical processes prone to chloride stress corrosion cracking or pitting corrosion, where standard SUS316L instruments prove inadequate.
Does the instrument include automatic temperature compensation?
No, automatic temperature compensation is not featured. The effects of process temperature variation on measurement must be independently assessed during system design.
What output types are available?
RS-232C digital output and 4-20mA analog output are provided, supporting direct SCADA/PLC integration.