In-line refractometer for IPA concentration monitoring in cleaning validation and disinfection processes. Delivers ±0.4% accuracy across 0-50% IPA range. Suitable for CIP/SIP and GMP processes.

  • 0.0-50.0% IPA concentration measurement range
  • ±0.4% accuracy, 0.1% resolution
  • SCADA/PLC integration via RS-232C and 4-20mA output
  • 1.32000-1.49100 RI measurement range
  • -15°C to 160°C operating temperature range
  • 10-35°C temperature compensation range

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The Atago CM-ISα-IPA is an in-line refractometer designed for continuous monitoring of isopropyl alcohol (IPA) concentration on the process line. This specialized version of the CM-800α series features RS-232C and 4-20mA outputs for seamless integration with SCADA/PLC systems.

The instrument provides measurements across 0.0-50.0% IPA range with ±0.4% accuracy and 0.1% resolution. The refractive index (RI) measurement range spans 1.32000-1.49100, and it operates across a wide temperature range from -15°C to 160°C. These characteristics make it a practical solution for applications requiring continuous and automated IPA concentration monitoring, such as cleaning validation, CIP/SIP processes, and disinfectant manufacturing.

The device does not feature automatic temperature compensation; IP65 protection rating is not specified. Installation environment planning should account for these limitations. When compensation range is specified, it is 10-35°C.

Technical Specifications

Manufacturer Atago
Model CM-ISα-IPA (CM-800α series)
IPA Measurement Range 0.0-50.0%
Accuracy ±0.4%
Resolution 0.1%
RI Measurement Range 1.32000-1.49100
Operating Temperature Range -15°C to 160°C
Temperature Compensation Range 10-35°C
Output RS-232C, 4-20mA

Applications

  • IPA cleaning validation (CIP/SIP)
  • Concentration monitoring in disinfection and disinfectant manufacturing processes
  • Process line IPA monitoring in pharmaceutical production areas

Frequently Asked Questions

What concentration range does the CM-ISα-IPA measure?
The instrument measures across the 0.0-50.0% IPA range with ±0.4% accuracy.
What output types are available?
RS-232C and 4-20mA outputs are available, enabling integration with PLC/SCADA systems.
Does the device have automatic temperature compensation?
According to available specifications, automatic temperature compensation is not included; when compensation range is specified, it is 10-35°C.