MycoSep® and MultiSep® Cleanup Columns

Fiyat Sorunuz

Single-step mycotoxin cleanup columns for food and feed analysis with rapid 30-second purification

  • Single-stage purification in 30 seconds
  • Selective adsorbent formulations for specific mycotoxin classes
  • Compatible with food and feed matrices
  • Two convenient column formats (MycoSep® and MultiSep®)
  • Minimal sample preparation required
  • Cost-effective bulk packaging (25 columns per pack)

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

MycoSep® and MultiSep® columns contain concentrated adsorbent material mixtures specifically formulated for all food and feed products. MycoSep® columns enable single-stage cleanup within 30 seconds: the cleanup column is inserted directly into a test tube containing the sample extract, forcing the extract through the column's chemical concentration matrix. Interfering compounds bind to the chemical adsorbent while purified extract containing target analytes passes through. MultiSep® column format provides equivalent single-stage cleanup of sample extracts containing target analytes within 30 seconds: sample extract is applied to the top of the MultiSep® cleanup column, interfering compounds bind to the column's chemical adsorbent, and purified extract containing analytes is collected in an appropriate container.

Technical Specifications

MycoSep® 112 AflaZON – Part No. COCMY2112
MycoSep® 112 AflaZON – Target Analytes Aflatoxins, Zearalenone
MycoSep® 112 AflaZON – Columns per Pack 25
MycoSep® 113 Trich – Part No. COCMY2113
MycoSep® 113 Trich – Target Analytes Trichothecenes Type A & B
MycoSep® 113 Trich – Columns per Pack 25
MycoSep® 150 Ergots – Part No. COCYM2150
MycoSep® 150 Ergots – Target Analytes Ergot Alkaloids
MycoSep® 150 Ergots – Columns per Pack 25
MycoSep® 224 AflaZON – Part No. COCYM2224
MycoSep® 224 AflaZON – Target Analytes Aflatoxins, Zearalenone
MycoSep® 224 AflaZON – Columns per Pack 25
MycoSep® 225 Trich – Part No. COCMY2225
MycoSep® 225 Trich – Target Analytes Trichothecenes Type A & B
MycoSep® 225 Trich – Columns per Pack 25
MycoSep® 226 AflaZON + – Part No. COCMY2226
MycoSep® 226 AflaZON + – Target Analytes Aflatoxins, Zearalenone
MycoSep® 226 AflaZON + – Columns per Pack 25
MycoSep® 227 Trich – Part No. COCMY2227
MycoSep® 227 Trich – Target Analytes Trichothecenes Type A & B
MycoSep® 227 Trich – Columns per Pack 25
MycoSep® 228 AflaPAT – Part No. COCMY2228
MycoSep® 228 AflaPAT – Target Analytes Aflatoxins, Patulin
MycoSep® 228 AflaPAT – Columns per Pack 25
MycoSep® 229 Ochra – Part No. COCMY2229
MycoSep® 229 Ochra – Target Analytes Ochratoxin A
MycoSep® 229 Ochra – Columns per Pack 25
MycoSep® 230 Niv – Part No. COCMY2230
MycoSep® 230 Niv – Target Analytes Nivalenol
MycoSep® 230 Niv – Columns per Pack 25
MycoSep® 231 Fum – Part No. COCMY2231
MycoSep® 231 Fum – Target Analytes Fumonisins
MycoSep® 231 Fum – Columns per Pack 25
MycoSep® 240 Mon – Part No. COCMY2240
MycoSep® 240 Mon – Target Analytes Moniliformin
MycoSep® 240 Mon – Columns per Pack 25
Cleanup Time 30 seconds
Purification Method Single-stage adsorbent-based cleanup

Applications

  • Aflatoxin analysis in cereals, nuts, and dried fruits
  • Zearalenone screening in grain samples
  • Trichothecene detection in wheat and barley
  • Ergot alkaloid quantification in feed ingredients
  • Ochratoxin A testing in coffee and cocoa
  • Fumonisin analysis in corn and corn-derived products
  • Patulin detection in apple juice and fruit products
  • Multi-mycotoxin regulatory compliance testing
  • Pre-analytical sample cleanup for HPLC/LC-MS
  • Food safety laboratory workflows
  • Feed quality control and certification

Frequently Asked Questions

What is the typical cleanup time required?
MycoSep® and MultiSep® columns provide complete single-stage purification in approximately 30 seconds per sample.
What is the difference between MycoSep® and MultiSep® formats?
MycoSep® columns are inserted directly into the sample extract-containing test tube, while MultiSep® columns are gravity-flow format where extract is applied to the top and purified extract is collected in a container below.
How many samples can be processed per pack?
Each package contains 25 columns, allowing processing of 25 individual samples.
Which column should I use for aflatoxin and zearalenone analysis?
MycoSep® 112 AflaZON or MycoSep® 224 AflaZON are recommended for simultaneous aflatoxin and zearalenone cleanup. MycoSep® 226 AflaZON + is an enhanced formulation for improved recovery.
Can these columns be used for multiple mycotoxin targets?
Each column is specifically formulated for targeted mycotoxin classes. Select the column matching your analytical target: aflatoxins, trichothecenes, ergot alkaloids, ochratoxins, fumonisins, patulin, nivalenol, or moniliformin.
Are these columns suitable for all food and feed matrices?
Yes, MycoSep® and MultiSep® columns contain adsorbent mixtures designed for compatibility with all food and feed product types.
Do I need any special equipment?
No special equipment is required. MycoSep® columns use simple mechanical insertion into test tubes. MultiSep® columns use gravity-flow collection into standard laboratory containers.