Stoklu siparişleriniz aynı gün kargoda!

Heating Block DHB230 3M™ Clean-Trace™

Fiyat Sorunuz

Digital heating block for 3M™ Clean-Trace™ surface protein allergen test strips with touch control and rapid heating capability

  • 230V operation with stainless steel and aluminum construction for rapid, uniform heating
  • Validated for use with 3M™ Clean-Trace™ Surface Protein (Allergen) Test Strip ALLTEC60
  • Heating consistency and accuracy enable results in 15 minutes or less
  • Touch control interface with digital temperature readout for precise adjustments
  • Accommodates 24 test strips simultaneously

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The 3M™ Clean-Trace™ Digital Heating Block DHB230 is a precision laboratory instrument designed for rapid and uniform heating of surface protein allergen detection assays. Engineered with a 230V stainless steel partition and aluminum block, it provides validated heating consistency for the ALLTEC60 test strips, enabling rapid allergen detection results in 15 minutes or less with digital temperature accuracy.

Technical Specifications

Power Supply 230V
Block Material Aluminum
Partition Material Stainless steel
Capacity 24 test strips
Control Type Digital touch control with display
Compatible Test Strips 3M™ Clean-Trace™ Surface Protein (Allergen) Test Strip ALLTEC60

Applications

  • Allergen detection in food processing environments
  • Surface protein contamination monitoring
  • Rapid allergen screening in laboratory and industrial settings
  • Validation of cleaning procedures in food manufacturing

Frequently Asked Questions

What is the heating time for 3M™ Clean-Trace™ test strips?
The DHB230 heating block enables result generation in 15 minutes or less when used with ALLTEC60 test strips, due to its optimized heating consistency and accuracy.
Is the DHB230 validated for ALLTEC60 test strips?
Yes, the heating block has been validated specifically for use with 3M™ Clean-Trace™ Surface Protein (Allergen) Test Strip ALLTEC60 to ensure reliable heating performance.
What temperature control features does it offer?
The unit features digital touch control and a digital readout display, allowing for precise and easy temperature adjustments.
How many test strips can be processed simultaneously?
The DHB230 can accommodate 24 test strips at once for parallel processing.