NucleoCounter® NC-200™ IQ/OQ Test Kit

Fiyat Sorunuz

Installation and Operational Qualification test kit for NucleoCounter® NC-200™ system validation

  • Complete IQ/OQ validation kit for NC-200™ system
  • Includes Via1-Cassettes™ for sample processing
  • Pre-configured IQ Cassettes for installation qualification
  • Fluorescent reference beads for system calibration verification
  • Comprehensive IQ/OQ test protocol included
  • Ensures compliance with manufacturer specifications

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The NucleoCounter® NC-200™ IQ/OQ Test Kit contains all components required to validate the Installation Qualification (IQ) and Operational Qualification (OQ) of the NucleoCounter® NC-200™ system. The kit includes one bag of Via1-Cassettes™, two IQ Cassettes, one IQ/OQ test plan, and one bottle of fluorescent reference beads. These components are used to perform documented verification that the instrument has been delivered and installed according to manufacturer specifications, and that the system's functional performance conforms to established acceptance criteria.

Technical Specifications

Kit Contents 1 bag Via1-Cassettes™, 2 IQ Cassettes, 1 fluorescent bead bottle, 1 IQ/OQ test plan
Compatible System NucleoCounter® NC-200™
Purpose Installation Qualification (IQ) and Operational Qualification (OQ)
Validation Type Hardware validation and functional performance testing

Applications

  • Initial system installation qualification and documentation
  • Operational qualification and performance verification
  • Preventive maintenance and system validation
  • Regulatory compliance documentation
  • System performance baseline establishment

Frequently Asked Questions

What is IQ in the context of this kit?
Installation Qualification (IQ) is documented evidence that the NucleoCounter® NC-200™ has been delivered and assembled in accordance with manufacturer specifications and design requirements.
What is OQ and why is it important?
Operational Qualification (OQ) is a systematic test procedure that verifies the instrument's functional performance meets manufacturer specifications under standard operating conditions.
When should the IQ/OQ kit be used?
The kit should be used during initial system setup, after major maintenance, or as part of periodic validation protocols to ensure continued compliance and performance.
What are fluorescent reference beads used for?
Fluorescent reference beads serve as calibration and performance verification standards, ensuring the NC-200™ system's detection and counting accuracy.