Stoklu siparişleriniz aynı gün kargoda!

PG INSTRUMENTS T60+ UV-VIS Split Beam Spectrophotometer

Fiyat Sorunuz

Precision split beam UV-VIS spectrophotometer for qualitative and quantitative analysis of organic and inorganic materials

  • Split beam optical system with fixed 2 nm spectral bandwidth
  • Wavelength range: 190-1100 nm with ±1 nm accuracy
  • Dual operation modes: UV-VIS and VIS
  • Motorized automated 8-position cell changer (standard)
  • Photometric measurement techniques: Transmittance, Absorbance, Energy
  • Integrated PC control with RS232 connection
  • PG UV Win Professional software included
  • Silicon photodiode detector with tungsten halogen and deuterium arc lamps
  • Photometric repeatability: 0.002A (0-0.5A), 0.004A (0.5-1.0A), 0.3%T (0-100%T)
  • Program card controlled system with PC software backup

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The spectrophotometer, developed since the 1950s, has become one of the most preferred precision analytical instruments in modern science laboratories. The T60+ is a split beam spectrophotometer designed according to the Lambert-Beer Law, which states that material absorbance depends on light wavelength, optical path length, and concentration. This versatile instrument features dual operation modes (UV-VIS and VIS), motorized automated 8-position cell changer, and integrated PC control capability. The T60+ series provides the most efficient methods for qualitative and quantitative analysis applications in research and industrial laboratories.

Technical Specifications

Optical System Split Beam
Scan Rate Fixed 2 nm
Wavelength Range 190-1100 nm
Wavelength Accuracy ±1 nm
Wavelength Repeatability ≤0.2 nm
Spectral Bandwidth 2 nm
Photometric Measurement Techniques Transmittance, Absorbance, Energy
Photometric Accuracy -0.3 – 3.0 Abs
Photometric Repeatability 0.002A (0-0.5A), 0.004A (0.5-1.0A), 0.3%T (0-100%T)
Photometric Sensitivity 0.001A (500 nm), 30 min warm-up
Baseline Sensitivity 0.002A (200-1000 nm)
Baseline Stability 0.001A/h (500 nm, 0 Abs), 2 hr warm-up
Stray Light Ratio ≤0.05%T (220 nm NaI, 340 nm NaNO2)
Standard Functions Photometric Measurement (Quantitative, Multi-wavelength, Spectrum and Kinetic measurements with program cards)
Cell Holder Motorized Automated 8-Position Cell Changer (Standard)
Detector Silicon Photodiode
Light Source Tungsten Halogen and Deuterium Arc Lamps
Display Digital LCD Display
Printer Optional Mini Printer
PC Connection RS232 Interface
Power Supply Switch Mode 95-250 VAC, 50-60 Hz
Weight 11 kg
Dimensions 476 mm × 362 mm × 225 mm
Software PG UV Win Professional Software (included in standard package)

Applications

  • Qualitative analysis of organic materials
  • Quantitative analysis of inorganic materials
  • Pharmaceutical compound identification and concentration determination
  • Environmental water quality analysis
  • Food and beverage quality control
  • Chemical composition analysis in research laboratories
  • Clinical and diagnostic testing
  • Spectroscopic kinetic measurements
  • Multi-wavelength analysis applications

Frequently Asked Questions

What is the difference between single beam and split beam spectrophotometers?
Single beam spectrophotometers measure reference and sample on the same light path sequentially. Split beam instruments divide the light source into two beams using a splitter, allowing simultaneous reading on two different detectors, which provides better accuracy and stability.
What does the Lambert-Beer Law describe?
The Lambert-Beer Law states that a material's absorbance is dependent on light wavelength, optical path length, and concentration. The T60+ is designed based on this fundamental principle for accurate photometric measurements.
What are the operating modes available on the T60+ series?
The T60+ offers two operation modes: UV-VIS (ultraviolet-visible) and VIS (visible only). Both modes provide identical optical performance with different spectral ranges.
Can the T60+ be controlled via computer?
Yes, the T60+ can be controlled either through program cards on the instrument itself or through PG UV Win Professional software on a computer via RS232 connection.
What is the photometric sensitivity specification?
The photometric sensitivity is 0.001A at 500 nm after 30 minutes of warm-up, indicating high precision for absorbance measurements in the visible range.
Does the T60+ include measurement techniques for kinetic studies?
Yes, the T60+ supports kinetic measurements through program cards, allowing users to monitor reaction rates and time-dependent photometric changes.
What is included in the standard package?
The standard package includes the spectrophotometer, motorized 8-position automated cell changer, and PG UV Win Professional software for PC control and data analysis.