Stoklu siparişleriniz aynı gün kargoda!

Luminescent Optical DO Probe APERA DO803 (3m)

Fiyat Sorunuz

Advanced optical dissolved oxygen probe with 3m cable for Apera DO850 and DO8500 portable meters. Non-consuming sensor technology for effortless operation.

  • Advanced luminescent optical DO sensor technology
  • Does not consume dissolved oxygen from solution
  • No minimum water flow rate requirement
  • Rapid stabilization in 1-3 minutes
  • Quick 1-2 minute calibration process
  • Simple operation - place and measure
  • 3-meter cable length for extended reach
  • Compatible with Apera DO850 and DO8500 meters

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The DO803 Luminescent Optical DO Probe is a replacement optical dissolved oxygen sensor designed for use with Apera DO850 and DO8500 portable optical DO meters. Utilizing state-of-the-art optical DO sensor technology, this probe offers significant advantages over traditional galvanic/polarographic sensors. The optical measurement principle eliminates oxygen consumption from the sample, requiring no water flow rate and enabling simple, straightforward operation.

Technical Specifications

Sensor Type Luminescent Optical DO
Cable Length 3m
Stabilization Time 1-3 minutes
Calibration Time 1-2 minutes
Compatible Models Apera DO850, DO8500

Applications

  • Water quality monitoring in aquaculture
  • Wastewater treatment plant monitoring
  • Laboratory dissolved oxygen analysis
  • Environmental water sampling
  • Bioprocess and fermentation monitoring
  • Continuous process control

Frequently Asked Questions

Does this probe consume oxygen from the sample?
No. The optical DO probe does not consume dissolved oxygen from the solution, eliminating measurement artifacts and the need for water circulation.
How quickly does the probe stabilize?
The probe stabilizes in 1-3 minutes, allowing for rapid measurement acquisition compared to traditional electrode-based sensors.
Is frequent calibration necessary?
No. The optical sensor technology requires only periodic calibration (1-2 minute calibration cycles), not constant adjustment.
What is the cable length specification?
The probe features a 3-meter cable, providing adequate reach for most laboratory and field applications.
Is water flow rate required?
No. The optical DO measurement principle does not require minimum water flow rates, simplifying installation and operation.