Optical DO Sensor Cap APERA DO802

Fiyat Sorunuz

Optical DO sensor membrane replacement cap for APERA DO803 and DO810 probes – 8000-hour service life with quick 2-minute installation

  • 8000-hour service life for reliable optical DO measurement
  • Compatible with APERA DO803 and DO810 optical dissolved oxygen probes
  • 2-minute quick replacement with data logger and flash drive setup
  • Eliminates manual data entry errors and delays
  • Maintains optical sensor accuracy and measurement reliability

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The DO802 Luminescent Optical DO Sensor Cap is an essential replacement component for Apera optical dissolved oxygen probes (models DO803 and DO810). With an 8000-hour service life, timely replacement ensures accuracy and reliability of your optical DO measurement instrument. Unlike traditional methods requiring manual data entry of dozens of parameters—a time-consuming and error-prone process—Apera offers a fast and convenient solution. Using the included data logger and flash drive-based installation firmware, sensor cap replacement can be completed in just 2 minutes, eliminating data entry delays and human error.

Technical Specifications

Model DO802
Type Luminescent Optical Sensor Cap
Compatible Probes DO803, DO810
Service Life 8000 hours
Installation Time 2 minutes

Applications

  • Replacement of worn optical DO sensor membrane for continued accurate measurement
  • Routine maintenance of dissolved oxygen measurement systems in water quality monitoring
  • Laboratory and field dissolved oxygen analysis in environmental testing
  • Aquaculture and wastewater treatment facility monitoring
  • Bioprocess and fermentation dissolved oxygen control

Frequently Asked Questions

How often should the DO802 sensor cap be replaced?
The DO802 sensor cap has an 8000-hour service life. Replacement frequency depends on usage patterns. Monitor measurement stability and replace when accuracy begins to drift or after 8000 operating hours, whichever comes first.
How long does it take to replace the sensor cap?
With the APERA data logger and flash drive installation system, sensor cap replacement can be completed in approximately 2 minutes, eliminating the need for manual data re-entry.
What probes are compatible with the DO802 sensor cap?
The DO802 is designed for use with APERA optical DO probes models DO803 and DO810.
Why is timely sensor cap replacement important?
Timely replacement ensures your optical DO measurement system maintains its accuracy and reliability. Worn or degraded sensor caps can produce erratic measurements and compromise data quality.
Do I need to re-enter calibration data when replacing the sensor cap?
No. The data logger with flash drive setup allows for quick calibration data transfer, eliminating the need for manual re-entry of dozens of parameters.