Stoklu siparişleriniz aynı gün kargoda!

APERA LabSen®231 pH Electrode for Wastewater, Suspension and Emulsion

Fiyat Sorunuz

Combination pH electrode with dual junction design for wastewater, emulsion, suspension, and protein/sulfur-containing samples

  • Long-lasting reference system with AgCl and silver reference wire for extended electrode service life
  • Polymer electrolyte with direct sample contact and pressure resistance up to 6 bar
  • Hemisphere glass membrane with exceptional impact resistance and high-temperature capability (up to 176°F)
  • Dual junction double-bridge construction prevents contamination from solid and liquid samples
  • Lead-free glass construction

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The LabSen 231 Combination pH Electrode, engineered with patented Swiss sensor technology and materials, is ideal for testing emulsions, suspensions, wastewater, and samples containing proteins and sulfur. The dual junction, dual-bridge structure features solid electrolyte that resists contamination and offers exceptional resistance to mechanical pressure. The long-lasting reference system and polymer electrolyte design provide extended service life and superior performance in challenging sample matrices.

Technical Specifications

Material Lead-free glass
Temperature Sensor No
Junction Type Dual
Reference System Long-lasting
Electrolyte Type Polymer
Electrode Length 120 mm
Electrode Diameter 12 mm
Membrane Shape Hemisphere
pH Range 0-14 pH
Temperature Operating Range -5 to 80°C (23 to 176°F)
Connector Type BNC
Cable Length 1 m

Applications

  • Wastewater and industrial effluent testing
  • Suspension sample analysis
  • Emulsion pH measurement
  • Protein-containing sample analysis
  • Sulfur compound sample testing
  • High-pressure process monitoring

Frequently Asked Questions

What makes the LabSen 231 suitable for wastewater applications?
The dual junction structure with polymer electrolyte and 6 bar pressure tolerance is specifically designed for wastewater testing. The solid electrolyte prevents clogging and contamination from suspended solids commonly found in wastewater samples.
Can this electrode be used in high-temperature samples?
Yes, the LabSen 231 features a hemisphere glass membrane and polymer electrolyte system capable of handling sample temperatures up to 80°C (176°F).
What is the advantage of the long-lasting reference system?
The AgCl/silver reference wire design with cotton-filled top prevents unwanted reactions between AgCl and electrolyte during temperature fluctuations, significantly extending electrode lifespan and maintaining stable reference potential.
Is this electrode suitable for protein and sulfur-containing samples?
Yes, the polymer electrolyte and dual junction design specifically prevent contamination from protein and sulfur compounds, making it ideal for biological and chemical sample analysis.